Friday, October 30, 2020

Work Permit System

 








Executor- Permittee
Whose job is to be done - Initiator






























































Shoring in excavation- put ply on hole sides
Benching- like steps on debris










Honey Bee
Electrical Lines
Hot Surface
Wind Velocity
Use of Crawling boards/ladder- For weight distribution
Always provide safety net & lifeline































Sunday, September 6, 2020

Design Review of FLP Lights


1. Seismic Activity

The latest version of seismic zoning map of India given in the earthquake resistant design code of India [IS 1893 (Part 1) 2002] assigns four levels of seismicity for India in terms of zone factors.

 In other words, the earthquake zoning map of India divides India into 4 seismic zones (Zone 2, 3, 4 and 5) unlike its previous version, which consisted of five or six zones for the country. 

According to the present zoning map, Zone 5 expects the highest level of seismicity whereas Zone 2 is associated with the lowest level of seismicity.



2. Enclosure Material of FLP Lights

Cast Al. LM6 

LM6


LM6

ALUMINIUM CASTING ALLOY LM6

This alloy conforms to BS 1490:1988 LM6.


CHEMICAL COMPOSITION

  % % %

 Copper 0.1 max Magnesium 0.10 max Silicon 10.0-13.0 

 Iron 0.6 max Manganese 0.5 max Nickel 0.1 max

 Zinc 0.1 max Lead 0.1 max Tin 0.05 max

 Titanium 0.2 max Aluminium Remainder Others each 0.5 max

 Others total 0.15 max         

 

LM24 Aluminium Guide Call To Action

MECHANICAL PROPERTIES OF ALUMINIUM (SAND & DIECASTING) ALLOY LM6

 


SAND CASTING


PRESSURE DIE CASTING


GRAVITY DIE CASTING


0.2% Proof Stress (N/mm2)


60-70


120


70-80


Tensile Strength (N/mm2)


160-190


280


190-230


Elongation (%)


5


2-5


7


Impact resistance Izod (Nm)


6.0


-


9.0


Brinell Hardness


50-55


55-60


55-60


Modulus of Elasticity (x103 N/mm2)


71


71


71


Shear Strength (N/mm2)


120


-


-


STRENGTH AT ELEVATED TEMPERATURES

Tensile strength and hardness of this aluminium casting alloy decreases fairly regularly with increasing temperature and become relatively poor at 250°C.


PHYSICAL PROPERTIES OF ALUMINIUM (SAND & DIE CASTING) ALLOY LM6

 


 


Coefficient of Thermal Expansion (per °C @ 20-100°C)


0.000020


Thermal conductivity (cal/cm2/cm/°C @ 25°C)


0.34


Electrical conductivity (% copper standard @ 20°C)


37


Density (g/cm3)


2.65


Freezing range (°C) approx.


575-565


LM24 Aluminium Guide Call To Action

MACHINABILITY

Aluminium alloys of this and similar compositions are rather difficult to machine, due to their tendency to drag and to the rapid tool wear caused by their high Silicon content. Carbide-tipped tools with large rake angles and low cutting speeds give comparatively good results when cutting lubricant and coolant are employed.


CORROSION RESISTANCE

Aluminium LM6 exhibits excellent resistance to corrosion under both ordinary atmospheric and marine conditions. For the severest conditions, this property can be further enhanced by anodic treatment.


ANODISING

LM6 can be anodised by any of the common processes, the resulting film ranging in colour from grey to dark brown.


APPLICATION AND GENERAL NOTES

Having high resistance to corrosion and excellent castability, aluminium LM6 is suitable for most marine 'on deck' castings, water-cooled manifolds and jackets, motor car and road transport fittings, thin section and intricate castings such as motor housings, meter cases and switch boxes, for a very large aluminium casting, e.g. cast doors and panels where ease of casting is essential, for chemical and dye industry castings, e.g. pump parts, and for paint industry and food and domestic castings. It is especially suitable for castings that are to be welded.


The ductility of LM6 enables castings to be rectified easily or even modified in shape, e.g. simple components may be cast straight and later bent to the required contour.


LM6 is equally adaptable for sand casting and aluminium die casting (gravity die casting and pressure die casting).


It has excellent resistance to corrosion in marine environments, possesses excellent ductility, but is of medium strength and is not heat treated. Its strength falls off rapidly at high temperatures. Its elastic limit is low and there is difficulty with machining.

Aluminium Casting Alloy LM6M has a high resistance to corrosion and excellent castability. 

It finds uses in numerous places due to these properties such as marine, manifolds, motor casings, cast doors, pumping applications. 

It is also especially suitable where castings need to be welded together.


3. Indian Standards

IS 6665 : Code of practice for industrial lighting 

IS 5571 : Selection of equipment in hazardous area. 

IS- 16101 : General lighting LEDs & LED modules terms & definition 

IS-16107.1 : General Requirement Part1 (2012) 

IS-16107.1 : Particular requirement section 1 LED luminaries Part2 (2012) 

IS 1610: 2012 : LED modules for general lights (Part 1) 

IS 1610: 2012 : LED modules for performance requirement (Part 2) 

IS 8224 : Electric lighting fittings for Div. 2 areas 

IS 10322 : Specification for luminaries (Part-1 to 4) 

IS 1913 : General safety requirements for luminaries

 IS 16102 : Self-Ballasts for LED lamps for Gen Lighting Services Part 1 : Safety Requirement Part 2 : Performance Requirement IS 8913 : Methods of measurement of lamp cap temperature rise 

IS 13947 : Degree of protection provided by enclosures for Switchgear & control gear 

IEC 60079 : Specification for Flameproof Enclosures of Electrical Apparatus /

 IS 2148 IEC 60079 – 7 : Specifications for Increased safety enclosures of electrical Apparatus /

 IS 6381 IS 62471 : Photo-biological safety of lamps and lamp systems




4. Temperature Class

Selection of Explosion Protected Equipment for Hazardous Locations - ppt  video online download

Zone vs Class / Division Instrumentation Tools



Saturday, August 22, 2020

Kapa

MIS Report

MTTR, MTBF, and MTTF

 

MTTR, MTBF, or MTTF? – A Simple Guide To Failure Metrics

Guide to failure metrics

Asset performance metrics like MTTR, MTBF, and MTTF are essential for any organization with equipment-reliant operations. Only by tracking these critical KPIs can an enterprise maximize uptime and keep disruptions to a minimum.

Tracking the reliability of assets is one challenge that engineering and maintenance managers face on a daily basis. While failure metrics can be very useful in this context, to use them effectively, you need to know what meaning hides behind their acronyms, how to distinguish between them, how to calculate them, and what does that tell you about your assets.



That’s why we decided to create a simple to follow guide to failure metrics that will help you avoid costly mistakes and successfully monitor equipment performance.

Introduction to Failure Metrics

Even the most efficient maintenance teams experience equipment failures. That’s why it’s critical to plan for them.

But first, what does equipment failure look like?

Failure exists in varying degrees (e.g. partial or total failure) but in the most basic terms, failure simply means that a system, component, or device can no longer produce specific desired results. Even if a piece of manufacturing equipment is still running and producing items, it has failed if it doesn’t deliver the expected quantities.

Managing failure correctly can help you to significantly reduce its negative impact. To help you effectively manage failures, there are a number of critical metrics that should be monitored. Understanding these metrics will eliminate guesswork and empower maintenance managers with the hard data they need to make informed decisions.

Which failure metrics should be tracked? Across industries and applications, we’ve found that those are MTTR, MTBF, and MTTF. We’ll discuss what each of those acronyms means and how you can use them to improve your operations.

But before that, we need to discuss one thing that is often overlooked – the importance of having reliable data behind your failure metrics.

The Importance of Reliable Data

In order to make data-backed improvements in equipment failure, it’s crucial for the right data to be collected and for that data to be accurate.

High-level failure statistics require a significant amount of meaningful data. As we’ll show in the failure metrics calculations below, the following inputs must be collected as part of your maintenance history:

  • Labor hours spent on maintenance
  • Number of breakdowns
  • Operational time (can be calculated from total expected operating hours per week –  total equipment downtime)
As tedious as recording maintenance figures can be, it’s an essential part of improving operations. This process can be painfully time-consuming when done manually, but it’s made simple with a mobile CMMS like Limble that lets you quickly and easily log reliable data for labor hours and downtime on your phone while you’re performing maintenance tasks. Additionally, Limble runs all the calculations of MTTR and MTBF automatically for you, as seen below.

Calculating failure metrics with Limble CMMS

Collecting inaccurate data can cause a lot of issues. Maintenance technicians might occasionally write down the wrong figure is just one example. A potentially much bigger problem is neglecting to record tasks, which leads to incomplete data.

If data is missing or inaccurate, your failure metrics will be useless in informing decisions on improving operations. Worse still, if you are unaware that the data is unreliable, you might end up making operational decisions that could actually be counterproductive and harmful.

Now that we got that out of the way, let’s focus on the things you actually came for.

30+ Most Commonly Used Maintenance Acronyms

Download Our Maintenance Acronym Guide

Did you know that MTTR can mean both “Mean Time To Repair” and “Mean Time To Recovery”?

What is the difference between “CBM” and “FTM”?

Download our list of all common maintenance acronyms.



What is Mean Time To Repair (MTTR)?

Mean Time To Repair (MTTR) refers to the amount of time required to repair a system and restore it to full functionality.

The MTTR clock starts ticking when the repairs start and it goes on until operations are restored. This includes repair time, testing period, and return to the normal operating condition.

How do you calculate MTTR?
To calculate MTTR, divide the total maintenance time by the total number of maintenance actions over a given period of time.

How to calculate MTTR

Imagine a pump that fails three times over the span of a workday. The time spent repairing each of those breakdowns totals one hour. In that case, MTTR would be 1 hour / 3 = 20 minutes.

A couple of things to note:

  • Typically, every instance of failure will vary in severity. So while some incidents will require days to repair, others could take mere minutes to fix. Hence, MTTR gives an average of what to expect.
  • To obtain reliable results, it’s important that every repair is handled by competent and trained personnel that can follow well-defined procedures.
Every efficient maintenance system always needs to look at how to reduce MTTR as much as possible. That can be done in a few different ways.

One approach is through tracking spare parts and inventory levels (thereby saving on downtime while sourcing for parts).

Another way is to implement proactive maintenance strategies like predictive maintenance. Predictive maintenance (PdM) will, among other things, allow you to better monitor the condition of in-service equipment and predict potential failure  more accurately by using condition-monitoring sensors mounted directly on those components that are prone to failure.

These sensors can alert them well in advance when to expect failure. At this point, the repair is no longer reactive but predictive, as the manager has enough time to arrange for all the resources needed to execute the job.

Why is MTTR helpful?
Taking too long to repair a system or equipment is not desirable as it can have a highly unpleasant impact on business results. This is especially the case for processes that are particularly sensitive to failure. It often results in production downtime, missed deadlines, loss of revenue and so on.

Understanding MTTR is an important tool for any organization because it tells you how efficiently you can respond to and repair any issues with your assets. Most organizations seek to decrease MTTR with an in-house maintenance team supported with the necessary resources, tools, spare parts, and CMMS software.

Maintenance managers can use MTTR to inform maintenance decisions such as:

  • when to repair or replace assets
  • quantity of parts and inventory to have on hand
  • whether to lease or buy equipment
Mean Time To Repair vs Mean Time To Recovery
There are several commonly used terms for the acronym “MTTR.” The two most common are “mean time to repair” (discussed above) and “mean time to recovery.”

Mean time to repair vs Mean time to recovery

Mean Time To Recovery is a measure of the time between the point at which the failure is first discovered until the point at which the equipment returns to operation. So, in addition to repair time, testing period, and return to normal operating condition, it captures failure notification time and diagnosis.

Although both terms are often used interchangeably, the need for distinction becomes important in the context of Service Level Agreements (SLAs) and maintenance contracts.

Hence, all parties to such contracts will need to agree on what exactly are they measuring.

What is Mean Time Between Failures (MTBF)?

The second failure metric we’ll cover is Mean Time Between Failures. MTBF measures the predicted time that passes between one previous failure of a mechanical/electrical system to the next failure during normal operation. In simpler terms, MTBF helps you predict how long an asset can run before the next unplanned breakdwon happens.

The expectation that failure will occur at some point is an essential part of MTBF.

The term MTBF is used for repairable systems, but it does not take into account units that are shut down for routine scheduled maintenance (re-calibration, servicing, lubrication) or routine preventive parts replacement. Rather, it captures failures that occur due to design conditions that make it necessary to take the unit out of operation before it can be repaired.

So, while MTTR measures availability, MTBF measures availability and reliability. The higher the figure of the MTBF, the longer the system will likely run before failing.

MTBF (Mean Time Between Failures)

How do you calculate MTBF?
Expressed mathematically, the lapses of time from one failure to the next can be calculated using the sum of operational time divided by the number of failures.

How to calculate MTBF

Looking at the example of the pump we mentioned under MTTR, out of the expected runtime of ten hours, it ran for nine hours and failed for one hour spread over three occasions. So, MTBF = 9 hours / 3 = 3 hours.

As you can see from the example above, the repair time is not included in the calculation of MTBF.

Apart from design conditions mentioned earlier, there are other common factors that tend to influence the MTBF of systems in the field.

A major one of these factors is human interaction. For instance, low MTBF could either indicate poor handling of the asset by its operators or a poorly-executed repair job in the past.

Why is MTBF helpful?
MTBF is an important marker in reliability engineering and has its roots in the aviation industry, where airplane failure can result in fatalities.

For critical assets such as airplanes, safety equipment, and generators, MTBF is an important indicator of expected performance. Therefore, manufacturers use it as a quantifiable reliability metric and as an essential tool during the design and production stages of many products. It is commonly used today in mechanical and electronic systems design, safe plant operations, product procurement and so on.

Even everyday decisions like buying a particular brand of car or computer are affected by the buyer’s desire for a product with a higher MTBF than what the next brand has to offer.

Although MTBF does not consider planned maintenance, it can still be applied for things like calculating the frequency of inspections for preventive replacements.

If it is known that an asset will likely run for a certain number of hours before the next failure, introducing preventive actions like lubrication or recalibration can help keep that failure to the minimum and extend the uptime of the asset.

What is Mean Time To Failure (MTTF)?

Mean Time To Failure (MTTF) is a very basic measure of reliability used for non-repairable systems. It represents the length of time that an item is expected to last in operation until it fails.

MTTF is what we commonly refer to as the lifetime of any product or a device. Its value is calculated by looking at a large number of the same kind of items over an extended period of time and seeing what is their mean time to failure.

Mean time to failure (MTTF)

In the manufacturing industry, MTTF is one of the many metrics commonly used to evaluate the reliability of manufactured products. However, there is still a lot of confusion in differentiating between MTTF and MTBF because they are both somewhat similar in definition. The good news is that this is easily resolved by remembering that while MTBF is used only when referring to repairable items, MTTF is used to refer to non-repairable items.

When using MTTF as a failure metric, repair of the asset is not an option.

How do you calculate MTTF?
MTTF is calculated as the total hours of operation, divided by the total number of items being tracked.

How to calculate MTTF

Let’s assume we tested three identical pumps until all of them failed. The first pump system failed after eight hours, the second one failed at ten hours, and the third failed at twelve hours.  MTTF in this instance would be (8 + 10 + 12) / 3 = 10 hours.

This would lead us to the conclusion that this particular type and model of the pump will need to be replaced, on average, every 10 hours.

The only surefire way to increase MTTF is to look for higher-quality items made from more durable materials.

Why is MTTF helpful?
MTTF is an important metric used to estimate the lifespan of products that are not repairable. Common examples of these products range from items like fan belts in automobiles to light bulbs in our homes and offices.

In particular, MTTF is important to reliability engineers when they need to estimate how long a component would last as part of a larger piece of equipment. This is especially true where the entire business process is sensitive to the failure of the equipment in question.

In such cases, MTTF becomes the primary indicator of the equipment’s reliability, with the aim to maximize asset lifetime. Shorter MTTF means more frequent downtime and disruptions.

Reduced Reactive Maintenance by 73.2%

See the Results Red Hawk Enjoys With Limble 



Final thoughts

One of the top priorities of maintenance managers is to ensure maximum operational availability of their equipment, as well as keeping equipment operations safe and efficient. Understanding the calculations and use of failure metrics will enable maintenance professionals to determine, with greater accuracy, when a critical asset is most likely to fail.

Based on their findings, they can proceed to develop better asset management strategies and improve their overall maintenance processes.

By calculating failure metrics and planning maintenance based on those results, they can also reduce their organization’s dependence on reactive maintenance in favor of planned (predictive) maintenance, which can be just the thing they need to spark their business’s growth.

If you are one of the many managers and technicians that are looking to improve these metrics by implementing a CMMS into their organization, you can start a free trial of Limble CMMS here or contact us for more information